ID: | AIXM-425 |
target version: | AIXM 5.2 |
version: | 1.0 |
last updated: | 10 OCT 2019 |
status: | APPROVED |
New codes for start/end twilight are added in the CodeTimeEventBaseType.
See https://aixmccb.atlassian.net/browse/AIXM-377
The meaning of 'day' and 'night' is not the same in the world. For European States that apply the "SERA Regulation" (European Union Commission Implementing Regulation (EU) No 923/2012), ‘night’ might actually mean "the hours between the end of evening civil twilight and the beginning of morning civil twilight. Civil twilight ends in the evening when the centre of the sun’s disc is 6 degrees below the horizon and begins in the morning when the centre of the sun’s disc is 6 degrees below the horizon."
In this case, different values are used for start/end event when coding HJ/HN codes. In AIXM 5.1(.1) OTHER has to be used:
[FWD_MAP_1:1] Data mapping is possible and no data loss occurs when data is exchanged from a system (A) that uses AIXM 5.1.1 for output towards a system (B) that uses AIXM 5.2 for input.
[BWD_MAP_1:1] Data mapping is possible and no data loss occurs when data is exchanged from a system (B) that uses AIXM 5.2 for output towards a system (A) that uses AIXM 5.1.1 for input.
In the UML model add the following code values to CodeTimeEventBaseType:
The additional values are shown in the UML class diagram to the right.
[MAPC-01] The following data conversion algorithm is proposed:
[MAPC-01] The following data conversion algorithm is proposed:
Mapping example
Mapping examples to be added... |
(Note: for mapping test data see: https://github.com/aixm/mapping_52_511/tree/master/AIXM-xxx)
AIXM 5.2 | AIXM 5.1(.1) | ||
---|---|---|---|
|
|